Choose a different country or region to see the content specific to your location
Current Region:
United Kingdom (EN)
This site uses some unobtrusive cookies to store information on your computer. By using the website, you hereby agree on cookies storage.
OK
Cookie Policy
Maintain Health & Safety in the Workplace!
Taking Your Workers from Hazard to Health
The Catalite@ Breathing Air Series Purifiers encompass Hankison's premium performance technology in order to provide the clean, dry air necessary to keep your workers safe. The CBA Series is designed to be used as an addition to your plant air source to convert compressed air to breathable air for those processes identified as hazardous.
Hankison's Catalite@ breathing air purifiers have been engineered to handle flow capacities from 15 to 940 scfm (25 to 1597 nm3/h) and remove contaminants in six stages of filtration in order to meet OSHA, CGA, ANSI, and CSA breathing air standards. At the core of the process is a heatless regenerative desiccant dryer with a fixed 10 minute dryer cycle delivering consistent ISO 8573-1: 2010 Class 2 (-40°F, -40°C) outlet pressure dew point quality air. Offering advanced controls and analyzers the Catalite® Breathing Air Purifier is the complete solution for your breathing air treatment processes.
This is equipment is intended for industrial applications only. Consult factory for non-industrial applications.
Application | Compressed Breathing Air Use |
---|---|
Power Generation |
Furnaces, boilers and holding tank workers use breathing air to guard against contaminated atmospheric conditions |
Petrochemical Manufacturing |
Protects workers from hazardous fumes, gases and vapors. |
Construction |
Workers require PPE for protection when working in asbestos abatement environments. |
Sandblasting/Spray Painting |
Protects workers from atomized VOC's emitted during this application process. |
General Industrial |
Confined spaces present hazardous breathing conditions when working in areas with poor air circulation, such as tanks, vats and boilers. |
Model No. | Inlet Flow1 |
Outlet Flow1 |
Voltages | In/Out Connections |
||
---|---|---|---|---|---|---|
SCFM | NM3/H | SCFM | NM3/H | V/PH/HZ | IN | |
CBA15 | 18 | 31 | 15 | 26 | 85-264/1/ 47-63 AC 11.5-28 V DC |
1 NPT |
CBA25 | 30 | 51 | 25 | 42 | 1 NPT | |
CBA35 | 42 | 71 | 35 | 59 | 1 NPT | |
CBA50 | 60 | 102 | 50 | 85 | 1 NPT | |
CBA75 | 90 | 153 | 75 | 127 | 1 NPT | |
CBA95 | 114 | 194 | 95 | 161 | 1 NPT | |
CBA135 | 162 | 275 | 135 | 229 | 1 NPT | |
CBA205 | 246 | 418 | 205 | 348 | 1.5 NPT | |
CBA305 | 366 | 622 | 305 | 518 | 2 NPT | |
CBA375 | 450 | 765 | 375 | 637 | 2 NPT | |
CBA490 | 590 | 1002 | 490 | 833 | 2 NPT | |
CBA625 | 750 | 1274 | 625 | 1062 | 2 NPT | |
CBA775 | 930 | 1580 | 775 | 1317 | 3 FLG | |
CBA940 | 1130 | 1920 | 940 | 1597 | 3 FLG |
1 Flow capacity rated at CAGI conditions: 100 psig (7.0 bar) and 100ºF (38ºC) saturated inlet
MODEL | DIMENSIONS | WEIGHT | ||||||
---|---|---|---|---|---|---|---|---|
H | W | D | ||||||
IN | MM | IN | MM | IN | MM | LBS | KG | |
CBA 15 | 49 | 1,244 | 42 | 1,067 | 35 | 889 | 440 | 200 |
MODEL | DIMENSIONS | WEIGHT | ||||||
---|---|---|---|---|---|---|---|---|
H | W | D | ||||||
IN | MM | IN | MM | IN | MM | LBS | KG | |
CBA 25 | 49 | 1,244 | 42 | 1,067 | 35 | 889 | 450 | 204 |
MODEL | DIMENSIONS | WEIGHT | ||||||
---|---|---|---|---|---|---|---|---|
H | W | D | ||||||
IN | MM | IN | MM | IN | MM | LBS | KG | |
CBA 35 | 49 | 1,244 | 42 | 1,067 | 35 | 889 | 455 | 206 |
Contaminants mg/m3 |
Maximum Allowable Concentration OSHA1 CSA |
Power Outlet Rated Conditions | |
---|---|---|---|
Carbon Monoxide(CO) |
10 |
5 |
95% Conversion5 |
Carbon Dioxide(CO2) |
1000 |
500 |
2 |
Oil(Condensed Hydrocarbons) |
5 |
1 |
0 |
Oil Vapor(Gaseous Hydrocarbons) |
____ |
____ |
< 0.023 |
Odor |
Lack of noticeable odor |
_4 |
1 OSHA Standard references CGA (Compressed Gas Association) pamphlet G-7.1, Grade D and is generally consistent with those published by ANSI
2 CO is converted to CO2 by the purifier and added to the concentration of CO2 already present (normal atmospheric air contains 314 mg/m3 of CO2 ) Although some CO2 is absorbed in the desiccant beds, high concentrations of CO in the system and/or high concentrations of CO2 at the compressor intake could result in exceeding allowable CO2 limits
3 Will remove only those gaseous hydrocarbons normally adsorbed by activated carbon. Outlet concentration is expressed as methane equivalent, Activated carbon will not remove methane
4 Will remove only those odors normally adsorbed by activated carbon
5 95% Conversion example (200 mg/m3 @ inlet = 10 mg/m3 @ outlet)
Model No. | Prefilters | Catalyst | Afterfilters | ||
---|---|---|---|---|---|
PF | UF | Cartridge | PF | CF | |
CBA15 | F02-PF-DG1 | F02-UF-DG1 | CC0 | F02-PF-TG1 | F02-CF-T |
CBA25 | F03-PF-DG1 | F03-UF-DG1 | CC0 | F03-PF-TG1 | F03-CF-T |
CBA35 | F04-PF-DG1 | F04-UF-DG1 | CC0 | F04-PF-TG1 | F04-CF-T |
CBA50 | F06-PF-DG1 | F06-UF-DG1 | CC1 | F06-PF-TG1 | F06-CF-T |
CBA75 | F07-PF-DG1 | F07-UF-DG1 | CC1 | F07-PF-TG1 | F07-CF-T |
CBA95 | F08-PF-DG1 | F08-UF-DG1 | CC2 | F08-PF-TG1 | F08-CF-T |
CBA135 | F10-PF-DG1 | F10-UF-DG1 | CC2 | F10-PF-TG1 | F10-CF-T |
CBA205 | F10-PF-DG1 | F10-UF-DG1 | CC3 | F10-PF-TG1 | F10-CF-T |
CBA305 | F12-PF-DG1 | F12-UF-DG1 | CC4 | F12-PF-TG1 | F12-CF-T |
CBA375 | F13-PF-DG1 | F13-UF-DG1 | CC5 | F13-PF-TG1 | F13-CF-T |
CBA490 | F14-PF-Z2G1 | F14-UF-Z2G1 | CC6 | F14-PF-G1 | F14-CF |
CBA625 | F14-PF-Z2G1 | F14-UF-Z2G1 | CC7 | F14-PF-G1 | F14-CF |
CBA775 | F15-PF-Z2G1 | F15-UF-Z2G1 | CC8 | F15-PF-G1 | F15-CF |
CBA940 | F16-PF-Z3G1 | F16-UF-Z2G1 | CC9 | F16-PF-G1 | F16-CF |
CO Monitor Base Model
Advanced Breathing Air Analyzer with Alarms
How Can We Help You?